Victoreen
®
943-25, 943-25A, 943-25B, 943-25T,
943-25TA, 943-25TB, 943-26, 943-26A,
943-26B, 943-26TT, 943-26TA, 943-26TB
Beta Detectors
Users Manual
March 2005
Manual No. 943-25-1 Rev. 2
©2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - Victoreen

Victoreen® 943-25, 943-25A, 943-25B, 943-25T, 943-25TA, 943-25TB, 943-26, 943-26A, 943-26B, 943-26TT, 943-26TA, 943-26TB Beta D

Page 2

Victoreen 943-25, 943-26 Operators Manual 2-2 2.3 Detector Operation - Replacement Parts Turn on channel power at the readout and slowly increase th

Page 3 - Table of Contents

Theory of OperationScintillator and Photomultiplier Tube3 3-1 Section 3 Theory of Operation 3.1 Scintillator and Photomultiplier Tube When

Page 4

Victoreen 943-25, 943-26 Operators Manual (Blank page)

Page 5 - Introduction

Maintenance, Calibration, and TroubleshootingMaintenance4 4-1Section 4 Maintenance, Calibration, and Troubleshooting 4.1 Maintenance There is no per

Page 6 - 1.4 Functional Description

Victoreen 943-25, 943-26 Operators Manual 4-2 5. Replace the four screws at the connector end of the detector. 4.2 Calibration The beta scintillat

Page 7 - 1.6 Storage

Maintenance, Calibration, and TroubleshootingCalibration Where Detector Is a Replacement Part4 4-34.4 Calibration Where Detector Is a Replacement Par

Page 8

Victoreen 943-25, 943-26 Operators Manual 4-4 4.6 Safety Related Detectors If the fault is isolated to the detector, repair can be performed by a t

Page 9 - Operation

Maintenance, Calibration, and TroubleshootingCommercial Detectors4 4-5Table 4-2. Recommended Test Equipment Feature Specification Pulse Generator (S

Page 10

Victoreen 943-25, 943-26 Operators Manual 4-6 3. Turn on channel power. 4. Using a pulse generator, inject negative pulses of -0.50 V amplitude, o

Page 11 - Theory of Operation

AppendixApplicable DrawingsA A-1Appendix A Applicable Drawings A.1 Applicable Drawings Detectors 943-25, 94-25T, 943-25A, 943-25B, 943-25TA, 943-2

Page 12 - (Blank page)

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564 120 A

Page 13 - Section 4

Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland, Ohio 44139 440.498.2564

Page 14 - 4.2 Calibration

iTable of Contents Section 1: Introduction... 1-1 1.1

Page 16 - 4.7 Commercial Detectors

IntroductionGeneral Description1 1-1Section 1 Introduction 1.1 General Description The 943 series beta detectors are designed to be sensitive to a b

Page 17 - 4.7.3 Preamplifier Checkout

Victoreen 943-25, 943-26 Operators Manual 1-2 Response Ratio: 1:1 943-25, 943-26, 943-25T, 943-26T 10:1 943-25A, 943-26A, 943-25TA, 943-26TA

Page 18 - 4.8 Replacement Parts

IntroductionFunctional Description1 1-3 Beta particles that have enough energy to penetrate the end window and impinge upon the disc will produce lig

Page 19 - Applicable Drawings

Victoreen 943-25, 943-26 Operators Manual 1-4 1.7 Procedures, Warnings, and Cautions The equipment described in this manual is intended to be used f

Page 20

OperationInstallation2 2-1Section 2 Operation 2.1 Installation Do not apply voltage to the detector if the mylar/titanium cover is not on the disc.